Reports until 18:32, Tuesday 11 August 2015
H1 INJ (INJ)
eric.thrane@LIGO.ORG - posted 18:32, Tuesday 11 August 2015 (20451)
EPICS down on h1hwinj1 (hwinj machine), restarted
Eric and Jim Batch

Eric wrote to Jim on Aug 10:

The ability to access EPICS channels appears to have disappeared at LHO when connected to h1hwinj:

[hinj@h1hwinj1 eric.thrane]$ ezcaread H1:CAL-INJ_TINJ_STATE
channel H1:CAL-INJ_TINJ_STATE not accessible

However, the same command works fine from cdsssh:

eric.thrane@cdsssh:~$ ezcaread H1:CAL-INJ_TINJ_STATE
H1:CAL-INJ_TINJ_STATE = 1

This problem appears to have occurred after ER7 since we would have seen errors during transient injections otherwise. Your assistance would be greatly appreciated.

Jim wrote back on Aug 11:

The problem has been resolved.  An update turned on some rather restrictive network filtering.