In order to determine how sensitive we are to activities at the site, and to help set rules for the O1 run, I injected human disturbances as recorded in the table below. DetChar, can you run these times to see if there are events detected in DARM for these activities? My timing should be good to within a second.
|
Injection |
Time of first injection Aug. 12 UTC |
Injection spacing (seconds) |
Injection session duration and number of injection (seconds, number) |
|
Truck (3808) horn at OSB recieving |
15:09:00 |
5 |
30, 6 |
|
Truck (3808) horn at 2k electronics room building |
15:09:00 |
5 |
30, 6 |
|
Truck (3808) sudden braking near 2k electronics building |
15:16:00 |
5 |
30, 6 |
|
Quick human moves in the optics lab next to the input arm |
15:23:00 |
5 |
60, 12 |
|
Human jumps in the change room |
15:25:00 |
5 |
60, 12 |
|
Silver van horn, 2k electronics building area |
17:04:00 |
5 |
30, 6 |
|
Silver van sudden brakes 2k electronics building area |
17:05:00 |
5 |
30, 6 |
|
Silver van horn, high-bay area |
17:08:00 |
5 |
30, 6 |
|
Siler van brakes high-bay area |
17:10:00 |
5 |
30, 6 |
|
Car door slams, patio area |
17:13:00 |
5 |
30, 6 |
|
Corolla car horn, parking area |
17:16:00 |
5 |
30, 6 |