Displaying report 1-1 of 1.
Reports until 05:12, Sunday 16 August 2015
H1 ISC
nutsinee.kijbunchoo@LIGO.ORG - posted 05:12, Sunday 16 August 2015 - last comment - 08:37, Sunday 16 August 2015(20565)
Turned off ETMY_L2_DAMP_MODE3 + changed gain in Guardian

I noticed that it has been sending several thousands of counts to the actuators. The modes are well damped so I changed the gain to 0 for now. I have reduced the gain of this filter in Guardian to be 100 but I have not reload the code becase I don't want to risk causing a lock loss tonight (I'm not sure if reloading the code will cause any glitches in the control signal).

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 08:37, Sunday 16 August 2015 (20568)

TJ hit the reload button. All is well.

Displaying report 1-1 of 1.