SUS Guardian issue

This morning after we restarted the ITM and ETM SUS models, the guardians failed when attempting to bring these SUSes back up.  It failed on all 4 QUAD SUS guardians at the same place when requesting to go from SAFE to ALIGNED:

 

2015-08-18T15:47:25.63598 SUS_ETMX [ENABLE_ALL.main] ezca: H1:SUS-ETMX_L2_TEST_L => ON: OUTPUT
2015-08-18T15:47:25.88943 SUS_ETMX [ENABLE_ALL.main] ezca: H1:SUS-ETMX_L2_TEST_P => ON: OUTPUT
2015-08-18T15:47:26.14962 SUS_ETMX [ENABLE_ALL.main] ezca: H1:SUS-ETMX_L2_TEST_Y => ON: OUTPUT
2015-08-18T15:47:26.40621 SUS_ETMX [ENABLE_ALL.main] ezca: H1:SUS-ETMX_L3_TEST_L => ON: OUTPUT
2015-08-18T15:47:26.65966 SUS_ETMX [ENABLE_ALL.main] ezca: H1:SUS-ETMX_L3_TEST_P => ON: OUTPUT
2015-08-18T15:47:26.91415 SUS_ETMX [ENABLE_ALL.main] ezca: H1:SUS-ETMX_L3_TEST_Y => ON: OUTPUT
2015-08-18T15:47:27.16605 SUS_ETMX [ENABLE_ALL.main] ezca: H1:SUS-ETMX_L3_TEST_BIAS => ON: OUTPUT
2015-08-18T15:47:27.16619 SUS_ETMX [ENABLE_ALL.main] Turning on OL damping outputs
2015-08-18T15:47:27.18074 SUS_ETMX W: Traceback (most recent call last):
2015-08-18T15:47:27.18076   File "/ligo/apps/linux-x86_64/guardian-1485/lib/python2.7/site-packages/guardian/worker.py", line 459, in run
2015-08-18T15:47:27.18077     retval = statefunc()
2015-08-18T15:47:27.18077   File "/ligo/apps/linux-x86_64/guardian-1485/lib/python2.7/site-packages/guardian/state.py", line 240, in __call__
2015-08-18T15:47:27.18078     main_return = self.func.__call__(state_obj, *args, **kwargs)
2015-08-18T15:47:27.18078   File "/opt/rtcds/userapps/release/sus/h1/guardian/SUS.py", line 456, in main
2015-08-18T15:47:27.18079     sus.olDampOutputSwitchWrite('ON')
2015-08-18T15:47:27.18079 NameError: global name 'sus' is not defined
2015-08-18T15:47:27.18080
2015-08-18T15:47:27.18762 SUS_ETMX ERROR in state ENABLE_ALL: see log for more info (LOAD to reset)

 

Reloading the GRD didn't work.  In order to get around this we Put the GRD to MANUAL and enabled the output switches by hand, then selected ALIGNING, anmd ALIGNED. 
 

Comments related to this report
jenne.driggers@LIGO.ORG - 10:13, Tuesday 18 August 2015 (20627)

This is now fixed. 

An object called "susobj" is defined early in the guardian, which contains the name of the optic.  In the new state ENABLE_ALL, the optical lever turn-on was mistakenly calling this object "sus" rather than "susobj".  3 extra characters, one click of the Load button, and ITMX went nicely from DAMPED to ALIGNED.

I have loaded the guardian code on ITMY as well, but *not* on the ETMs, since charge measurements are in progress.

UPDATE: ETMX and ETMY guardians were loaded, after charge measurements were complete.