Reports until 10:58, Tuesday 18 August 2015
H1 AOS
betsy.weaver@LIGO.ORG - posted 10:58, Tuesday 18 August 2015 (20632)
DARM_DAMP_MODE gains

After the QUAD front end restarts, we found that some of the DARM DAMP MODE loops were blasting the suspension.  In these cases, the FE was restoring non-zero gains as per the safe.snap settings file.  Since Jenne confirmed that the GUARDIAN sets these gains and turns these loops on, I have written all of the gains to be ZERO in the safe.snaps for future restarts.