tonight's AS36 Yaw input matrix

Jeff K, Jeff B, Dan, Jenne, Sheila

 -3.4 AS36 A I and -1 AS36 B I.  Note that the sign has flipped for AS36B.  

We can not use this matrix at 3 Watts, but it has been better consistently tonight at 15 Watts and above than the original, which was -3 ASA36I +-0.5 AS36BI.  I've added a few lines to the increase power state that changes this matrix once the power is above 15 Watts. 