Went through the SDF to see if I could make sense of the differences on there. I did not make anything GREEN (i.e. I did not ACCEPT or REVERT anything because I'm not sure whether we want Operators to do this or Detector Engineers to do that).
Here are some of my notes of Differences we have by subsystem:
SUSITMY
SUSITMX
-
H1:SUS-ITMY_L2_DAMP_MODE1 (8/19 15:24): violin?? Revert or Accept?
-
H1:SUS-ITMY_L2_DAMP_MODE7 (8/19 14:36): violin?? Revert or Accept?
-
H1:SUS-ITMY_L2_DAMP_MODE9_GAIN: Can't find alog (8/20 16:31PST)
SUSETMX
-
H1:SUS-ETMX_L2_DAMP_MODE10: IN? What does this mean?
-
H1:SUS-ETMX_L2_DAMP_MODE7: IN? What does this mean?
-
H1:SUS-ETMX_L2_DAMP_MODE8: IN? What does this mean?
-
H1:SUS-ETMX_L2_DAMP_MODE9: Nutsinee violin damping (8/20 16:20PST). Are we happy with this and can we accept?
SUSETMY
SUSSR3
-
H1:SUS-SR3_M2_OLDAMP_P_GAIN (8/19 14:38): ??
-
H1:SUS-SR3_M2_TEST_P_GAIN (8/19 14:36): ??
LSC
-
H1:LSC-MCL_TRAMP (8/20 16:31): ?? Can we revert?
ASC
-
H1: ASC-INMATRIX_P_5_3 (8/20 16:52): ?
-
H1: ASC-INMATRIX_P_5_8 (8/20 16:52): ?
-
H1: ASC-INMATRIX_Y_16_3 (8/19 0:31): ?
-
H1: ASC-INMATRIX_Y_16_7 (8/19 0:31): ?
-
H1:ASC_MICH_P_OFFSET (8/19 22:16): ?
-
H1:ASC_MICH_Y_OFFSET (8/19 21:11): ?
OMC
-
H1:OMC-DCPD_A (8/20 17:16): ?
-
H1:OMC-DCPD_B (8/20 17:15): ?
CALCS
Lots of channels here. Seems like many can be ACCEPTED
As usual, the SDF stuff just needed some investigation. During the last few Intent drops, I cleared some SDF stuff in Corey's alog 20736. Usually we don't have to go into such detail, but since there were a lot of question marks by each, I am adding a few notes of why things were accepted below.
Here's what I have found after hunting things down and double checked a few things with TEAM-COMMISS:
ACCEPTED New violin stuff SUSITMY
ACCEPTED New violin stuff SUSETMX
ACCEPTED New violin stuff SUSETMY
ACCEPTED This is the revert to turn the CAGE servo OFF and the OLDAMP servo ON SUSSR3
ACCEPT Tramps are not a big deal. If they are, then they are written into the Guardian and therefore can be ignored anyways. LSC
CLEARED ASC
ACCEPTED See attached snap - an additional stage of whitening is ON (the 2nd of 3), Stefan says this will likely stay on. OMC
OMC DCPD - In fact, we have now just set SDF to NOT MON these switches since Evan/Stefan say they will be switching whitening states during different lock stretches as needed, in Guardian.