Displaying report 1-1 of 1.
Reports until 00:55, Saturday 22 August 2015
H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 00:55, Saturday 22 August 2015 (20777)
Power increase with BS and SRM dither lines
We ran dither lines for BS and SRM during the power increase, as well as during the 45MHz EOM modulation depth reduction:

Lines:
H1:SUS-SRM_M3_ISCINF_P_EXC 7.0Hz, 300cts
H1:SUS-SRM_M3_ISCINF_Y_EXC 7.5Hz, 900cts
H1:SUS-BS_M3_ISCINF_P_EXC  8.0Hz, 100cts
H1:SUS-BS_M3_ISCINF_Y_EXC  8.5Hz,  30cts

Lines started by        2015/08/22 06:23 UTC
Start PWR UP:           2015/08/22 06:24 UTC
Stop PWR UP:            2015/08/22 06:26 UTC
Start EOM MOD:          2015/08/22 07:02 UTC
Stop  EOM MOD (-4dB):   2015/08/22 07:11 UTC
Lock loss:              2015/08/22 07:15 UTC

The EOM reduction reached -3dB, and was lost due to a SRC1_Y run-away.

Attached are (all plots have 72 min span, halting just before lockloss):
- Plot 1: AS RF36 PIT and YAW signals, plus the ASAIR_A_LF_OUTPUT for reference, showing i) power increase, ii)  beam diverter closing, and reopening, iii) modulation index reduction.
= Plot 2: All quadrants of the AS36 WFS, on the same scale
More details later.
Images attached to this report