DQ Shift 20 August 00:00 UTC - 23 August 23:59 UTC

- Duty Cycle: 54%

- range: 75 - 85 Mpc

- PRM M3 LL coil driver caused noise in 10-60 Hz range on Friday, may have been responsible for some loud glitches

- Also on Friday there were some strange lines in the strain spectrogram at around 10Hz

- loud glitches that cause brief, large drop in range that we saw in ER7 continue; the rate is improved

- link to full DQ shift

Comments related to this report
sheila.dwyer@LIGO.ORG - 12:30, Monday 24 August 2015 (20824)CAL

Please note that the range on the summary pages is not correct.  The range displayed in the control room has been hovering around 60-65 Mpc, and this is much more realistic, although not yet blessed by the calibration group. 