Displaying report 1-1 of 1.
Reports until 10:30, Wednesday 26 August 2015
H1 TCS (TCS)
alastair.heptonstall@LIGO.ORG - posted 10:30, Wednesday 26 August 2015 - last comment - 20:41, Wednesday 26 August 2015(20920)
TCS Chiller output channels - limit added

After some email communication with Keith Thorne and Elli, I've added limits at 32,500 to the channels L1:TCS-ITMX_CO2_CHILLER_OUT_GAIN_OUT and its y-arm sibling.  This has also been done at LLO.

These channels have a static output on them, and are used to set the chiller temperature for the TCS CO2 lasers.  The value is not changed, and will not be at all affected by the limit being put in place. 

 

 

Comments related to this report
patrick.thomas@LIGO.ORG - 17:44, Wednesday 26 August 2015 (20929)
Do we want to accept the SDF differences (see attached) for this change?
Images attached to this comment
alastair.heptonstall@LIGO.ORG - 19:26, Wednesday 26 August 2015 (20933)

Yes, those are the channels where I changed the values for limits in the filters.

patrick.thomas@LIGO.ORG - 20:41, Wednesday 26 August 2015 (20935)
Accepted
Displaying report 1-1 of 1.