Displaying report 1-1 of 1.
Reports until 18:08, Thursday 27 August 2015
H1 SUS (SUS, SYS)
leonid.prokhorov@LIGO.ORG - posted 18:08, Thursday 27 August 2015 - last comment - 21:16, Thursday 27 August 2015(20968)
OPLEV charge measurements
Charge measurements was done on both ETMs.
It seems like ETMY change the sign of charging after changing the bias sign on ETMY (see 20387) while ETMX charging is the same (as well as the bias sign).
Now (since Aug,10) both ETMX and ETMY Biases are -9.5V, 
Plots are in attachment.
Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 21:16, Thursday 27 August 2015 (20970)

Since we turn teh ESD in X off during a lock stretch, could it be that ETMX has been used less since the start of ER8?

Displaying report 1-1 of 1.