J. Kissel, K. Izumi We've completed another round of the suite of actuation coefficient coefficient measurements today, very similar to what was done on Wednesday (see LHO aLOG 20940) with the same templates. There were some differences between the two days worth of measurements -- we don't expect these to have made a difference, but we've been living 1% accuracy and precision land for a week with no sleep, so we write them down anyways. They are: - We managed to get all of the full IFO transfer function measurements within the same lock stretch, unlike Wednesday. - We did Full IFO config measurements, ALS DIFF measurements, then Free-Swinging MICH (FSM) measurements, as opposed to Wednesday when we did DIFF, then Full, then FSM. - Because we got distracted with full-frequency range DARM OLG and PCAL to DARM TFs, and there were some problems with DIFF saturating, there were about ~4 hours between when the ETMX TF was taken in full lock and when it was taken in ALS DIFF. - On Wednesday, we ran ALS DIFF with ALS COMM OFF. Today we ran ALS DIFF with ALS COMM ON. - We missed a MICH OLG TF for the FSM. We may try to get away with checking if the power and PD normalization levels are the same -- if they are we may just use Wednesday's data. Otherwise it means we have to scrap all of today's FSM data. A "When will you have a number?" update: we are heavy into analyzing both of the data sets (ALS DIFF is done with the help of LHO aLOG 21001, tomorrow will be PCAL and FSM). A goal is to have a comparison between methods by Sunday. For a sneak peak on the analysis scripts for ALS DIFF (in case LLO wants to use them), check out /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Scripts/ALSDiff analyze_alsdiff_data_20150826.m analyze_alsdiff_data_20150828.m #NoSleepTilO1 The DTT files live here: (2) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FullIFOActuatorTFs/2015-08-28/ 2015-08-28_H1SUSETMY_PCALYtoDARM_FullLock.xml (5) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/ALSDIFF/2015-08-28/ 2015-08-28_ALSDiff_ETMX_L3_HVHN.xml (6) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FreeSwingMich/2015-08-28/ 2015-08-26_H1MICH_freeswingingdata.xml (7) Does not Exist (8) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FreeSwingMich/2015-08-28/ 2015-08-28_H1SUSITMX_L2_State2_MICH.xml (9) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FreeSwingMich/2015-08-28/ 2015-08-28_H1SUSITMX_L2_State2_XARM.xml (10) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FreeSwingMich/2015-08-28/ 2015-08-28_H1SUSETMX_L3_HVHN_XARM.xml (X) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FullIFOActuatorTFs/2015-08-28/ 2015-08-28_H1SUSETMY_L3toDARM_LVLN_LPON_FullLock.xml (Y) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FullIFOActuatorTFs/2015-08-28/ 2015-08-28_H1SUSETMY_L1toDARM_FullLock.xml 2015-08-28_H1SUSETMY_L2toDARM_FullLock.xml (Z) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER8/H1/Measurements/FullIFOActuatorTFs/2015-08-28/ 2015-08-28_H1SUSETMX_toDARM_FullLock.xml Wish us luck on tomorrow's measurement suite; hopefully it'll be the last time for while!
Just for booking purpose.
In addition to the measurements that Jeff posted, I have done a Pcal Y sweep and DARM open loop measurements in a frequency band of [7 800] Hz using Darkhan's template. The data can be found at:
aligocalibration/trunk/Runs/ER8/H1/Measurements/PCAL/2015-08-28_PCALY2DARMTF_7to800Hz.xml
aligocalibration/trunk/Runs/ER8/H1/Measurements/DARMOLGTFs/2015-08-28_H1_DARM_OLGTF_7to800Hz.xml