Displaying report 1-1 of 1.
Reports until 16:06, Friday 28 August 2015
H1 SEI (CDS, PEM)
evan.hall@LIGO.ORG - posted 16:06, Friday 28 August 2015 - last comment - 21:08, Sunday 30 August 2015(20997)
DMT viewer template for STS BLRMS

Jeff, Evan

There is now a new DMT viewer template for viewing the BLRMS of the corner and end-station STSs. It is userapps/isc/h1/scripts/Seismic_FOM_STS.xml.

This is meant to replace the Guralp DMT viewer template.

Right now it only displays the lowest two BLRMS (0.03 to 0.1 Hz and 0.1 to 0.3 Hz).

[As an aside, the frequency bands implied by the channel names in DMT viewer don't seem to match up with the front-end channels. For example, the front-end EX-X channels are named as follows:

H1:ISI-GND_STS_ETMX_X_BLRMS_100M_300M
H1:ISI-GND_STS_ETMX_X_BLRMS_10_30
H1:ISI-GND_STS_ETMX_X_BLRMS_1_3
H1:ISI-GND_STS_ETMX_X_BLRMS_300M_1
H1:ISI-GND_STS_ETMX_X_BLRMS_30_100
H1:ISI-GND_STS_ETMX_X_BLRMS_30M_100M
H1:ISI-GND_STS_ETMX_X_BLRMS_3_10

while the DMT channels are named as follows:

H1:ISI-GND_STS_ETMX_X_DQ_0p03-0p1Hz_48h
H1:ISI-GND_STS_ETMX_X_DQ_0p1-0p2Hz_48h
H1:ISI-GND_STS_ETMX_X_DQ_0p2-0p35Hz_48h
H1:ISI-GND_STS_ETMX_X_DQ_0p35-1Hz_48h
H1:ISI-GND_STS_ETMX_X_DQ_1-3Hz_48h

Are these BLRMS distinct from what's being computed in the frontend?]

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 21:29, Friday 28 August 2015 (21002)

What was wrong with the old plot?

evan.hall@LIGO.ORG - 22:09, Friday 28 August 2015 (21003)

The STS is more sensitive than the Güralp in the frequency band where we typically watch for earthquakes (30 mHz to 100 mHz).

daniel.sigg@LIGO.ORG - 21:08, Sunday 30 August 2015 (21040)

Looks like we should keep the old plot then, since everyoe already knows it.

Displaying report 1-1 of 1.