Reports until 22:33, Monday 31 August 2015
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 22:33, Monday 31 August 2015 - last comment - 22:37, Monday 31 August 2015(21075)
h1nds1 continues to be unstable

h1nds1 daqd process stopped running at 21:47 this evening

computer did not lock up. I logged in and started the process but it quickly stopped again.

I restarted a second time and now it is running. Investigation is continuing.

Monit is not restarting the process, as root I started with /etc/init.d/daqd_nds1 start

Comments related to this report
david.barker@LIGO.ORG - 22:37, Monday 31 August 2015 (21076)

If h1nds1 stops running overnight and will not restart itself we have two options:

  1. switch over to using h1nds0 as your NDS server (this is not the default, so you will have to force your client to use this)
  2. reboot h1nds1 computer by going into the MSR and pressing the RESET switch on the front panel. Computer is clearly marked and is in the 5th rack from far wall.