To better manage the H1 IFO configuration changes during ER8 and into O1 I have committed all pending modifications of source files, filter files and safe.snap files into SVN.
Turns out I was the main culprit for model changes not being committed, the changes I made yesterday to odcmaster and pemcs had not been committed, nor my change some time ago to calex to add the irig-b channel to the science frame. I have committed these today.
The filter files for the new PI models were still static files in the chans directory. I moved them to the userapps/sus/h1/filterfiles area, made the symbolic link and committed them to SVN. The CFC bit was raised during this shuffle, so the DIAG_RESET button for both PI models were pressed to clear this bit.
All remaining local mods to filter and safe.snap have been committed with a generic "version as of 02sep2015 ER8" message applied.