After the Earth settled down, I ran through an initial alignment (including dither alignment of TMSy) since the green alignment wasn't very good. Lots of locklosses on the way up at various places.
11:48 Dan leaves for Italy
12:00 Begin initial alignment
12:08 I notice that ALS_-Y_WFS_DOF_3_P_GAIN and ALS_-Y_WFS_DOF_3_Y_GAIN are flagged in SDF. I assume this is a result of the dither alignment of TMSy. I revert them.
13:12 lockloss @ SWITCH_TO_QPDS
13:25 lockloss @ RF_DARM
13:36 lockloss @ DRMI_ON_POP, possibly due to PRM saturation
13:43 lockloss @ SWITCH_TO_QPDS
13:46 lockloss @ FIND_IR
13:54 lockloss @ SWITCH_TO_QPDS
14:13 ISC_LOCK is stalled at DC_READOUT_TRANSITION. Looking at the code and OMC_LOCK log, I try re-requesting READY_FOR_HANDOFF in OMC_LOCK. It works, and ISC_LOCK carries on.
14:16 lockloss at ENGAGE_ISS_2ND_LOOP, conicident ETMy saturation
14:18 Seismos start showing more activity. USGS site reports another 6.2 EQ in New Zealand. The thunder from down under does us in again.
14:47 Observatory mode set to Earthquake
15:00 Good luck Ed!