late entry for yesterday's CDS maintenance
DAQ frame writer install
Dave, Jim:
The second fast frame writer was connected to the LDAS Sataboy-raid system. All frame writers were then renamed, details in Jim's alog
Adding Duotone Channels to the Science Frame
Keita, Dave:
The h1omc, h1calex and h1caley models were modified to all DUOTONE timing signals from all three buildings to the science frame at 16kHz. These signals are being readout by a filtermodule, to capture the raw signal before any filtering/gain/offset could be applied, we are using the IN1 channel.
H1CALEX.ini:[H1:CAL-PCALX_FPGA_DTONE_IN1_DQ]
H1CALEY.ini:[H1:CAL-PCALY_FPGA_DTONE_IN1_DQ]
H1OMC.ini:[H1:OMC-FPGA_DTONE_IN1_DQ]
Loading all the filters
Sheila, Dave:
SUS PRM and SRM had partially loaded filters, we performed a full load of these systems.
Restarted External Alerting System
Dave:
I restarted the external alert system which had stopped between 6pm and 7pm PDT Monday. I'm looking into a mechanism to restart this system.