Since turning up the bandwidth of the AS_C → SR2 loops, we had not engaged cutoff filters. There are now 18 Hz elliptic LPFs installed for both pitch and yaw. They are turned on the ISC LOCK guardian just after the final gain increase of the yaw loop.