Screenshot of ops overview and list of HEPIs/ISIs/Optics that are tripped.
From the time optics started to trip, until the last optic tripped, was a total of 18 seconds.
Five optics tripped at 8:26:26UTC - eight optics tripped at 8:26:44, which could have gone to safe mode, if I could have clicked faster.
I am proposing we add the capability of putting all optics in safe mode with one button, once it's clear an earthquake is going shake enough to trip optics.
Seismic traces are now off the top of the plot and a number of watchdogs tripped. All optics are now either tripped or in safe mode.
There are now 3 big earthquakes:
Screenshot of ops overview and list of HEPIs/ISIs/Optics that are tripped.
From the time optics started to trip, until the last optic tripped, was a total of 18 seconds.
Five optics tripped at 8:26:26UTC - eight optics tripped at 8:26:44, which could have gone to safe mode, if I could have clicked faster.
I am proposing we add the capability of putting all optics in safe mode with one button, once it's clear an earthquake is going shake enough to trip optics.