ETMY R0, L1, L2 Open Light counts
ETMY R0, L1, L2 Open Light counts, offsets, and normalising gain values.  Offsets are calculated by dividing the open light counts by two and multiplied by (-1).  The gain values are calculated such that the open light counts are normalised to 30,000cts.
-----------------------------------------------------------
R0 
controls@cdsws1:~ 0$ tdsavg 30 H2:SUS-ETMY_R0_OSEMINF_F1_IN1 H2:SUS-ETMY_R0_OSEMINF_F2_IN1 H2:SUS-ETMY_R0_OSEMINF_F3_IN1 H2:SUS-ETMY_R0_OSEMINF_LF_IN1 H2:SUS-ETMY_R0_OSEMINF_RT_IN1 H2:SUS-ETMY_R0_OSEMINF_SD_IN1
29408.9
26594.2
28718
28591
27628.8
29841.9

OSEMINF OFFSETS:
F1 = -14705
F2 = -13297
F3 = -14359
LF = -14296
RT = -13815
SD = -14921

OSEMINF GAINS:
F1 = 1.020
F2 = 1.128
F3 = 1.045
LF = 1.049
RT = 1.086
SD = 1.005
-------------------------------

L1
tdsavg 30 H2:SUS-ETMY_L1_OSEMINF_UL_IN1 H2:SUS-ETMY_L1_OSEMINF_UR_IN1 H2:SUS-ETMY_L1_OSEMINF_LL_IN1 H2:SUS-ETMY_L1_OSEMINF_LR_IN1
30801.6
26947.8
31350.3
32767

OSEMINF OFFSETS:
UL = -15401
UR = -13474
LL = -15675
LR = -16384

OSEMINF GAINS:
UL = 0.974
UR = 1.113
LL = 0.957
LR = 0.916
------------------------------

L2
controls@cdsws1:~ 0$ tdsavg 30 H2:SUS-ETMY_L2_OSEMINF_UL_IN1 H2:SUS-ETMY_L2_OSEMINF_UR_IN1 H2:SUS-ETMY_L2_OSEMINF_LL_IN1 H2:SUS-ETMY_L2_OSEMINF_LR_IN1
23679.1
23181.5
26177.6
23786

OSEMINF OFFSETS:
UL = -11840
UR = -11591
LL = -13089
LR = -11893

OSEMINF GAINS:
UL = 1.267
UR = 1.294
LL = 1.146
LR = 1.261
Displaying report 1-1 of 1.