ETMY R0, L1, L2 Open Light counts, offsets, and normalising gain values. Offsets are calculated by dividing the open light counts by two and multiplied by (-1). The gain values are calculated such that the open light counts are normalised to 30,000cts. ----------------------------------------------------------- R0 controls@cdsws1:~ 0$ tdsavg 30 H2:SUS-ETMY_R0_OSEMINF_F1_IN1 H2:SUS-ETMY_R0_OSEMINF_F2_IN1 H2:SUS-ETMY_R0_OSEMINF_F3_IN1 H2:SUS-ETMY_R0_OSEMINF_LF_IN1 H2:SUS-ETMY_R0_OSEMINF_RT_IN1 H2:SUS-ETMY_R0_OSEMINF_SD_IN1 29408.9 26594.2 28718 28591 27628.8 29841.9 OSEMINF OFFSETS: F1 = -14705 F2 = -13297 F3 = -14359 LF = -14296 RT = -13815 SD = -14921 OSEMINF GAINS: F1 = 1.020 F2 = 1.128 F3 = 1.045 LF = 1.049 RT = 1.086 SD = 1.005 ------------------------------- L1 tdsavg 30 H2:SUS-ETMY_L1_OSEMINF_UL_IN1 H2:SUS-ETMY_L1_OSEMINF_UR_IN1 H2:SUS-ETMY_L1_OSEMINF_LL_IN1 H2:SUS-ETMY_L1_OSEMINF_LR_IN1 30801.6 26947.8 31350.3 32767 OSEMINF OFFSETS: UL = -15401 UR = -13474 LL = -15675 LR = -16384 OSEMINF GAINS: UL = 0.974 UR = 1.113 LL = 0.957 LR = 0.916 ------------------------------ L2 controls@cdsws1:~ 0$ tdsavg 30 H2:SUS-ETMY_L2_OSEMINF_UL_IN1 H2:SUS-ETMY_L2_OSEMINF_UR_IN1 H2:SUS-ETMY_L2_OSEMINF_LL_IN1 H2:SUS-ETMY_L2_OSEMINF_LR_IN1 23679.1 23181.5 26177.6 23786 OSEMINF OFFSETS: UL = -11840 UR = -11591 LL = -13089 LR = -11893 OSEMINF GAINS: UL = 1.267 UR = 1.294 LL = 1.146 LR = 1.261