Displaying report 1-1 of 1.
Reports until 00:01, Monday 14 September 2015
LHO General
corey.gray@LIGO.ORG - posted 00:01, Monday 14 September 2015 (21474)
EVE Ops Summary
TITLE:  9/13 EVE Shift:  23:00-7:00UTC (16:00-0:00PDT), all times posted in UTC

STATE OF H1:  No Observation Mode during this shift.  Continue recovery from earthquake, but H1 appears to get lock (~72Mpc), albeit with some new issues (see below).

SUPPORT:  Jenne, Sheila, Jeff K, Evan, & Stefan

SHIFT SUMMARY:    Another shift of recovery.  Evan & Stefan did some measurements on H1 & also some troubleshooting.  Lock Acquisition is not optimum & we have a few issues:

  1. SRM saturations & watchdog trips (had it happen to me when I realigned SRM while tweaking in PRMI)
  2. Problem with Finding IR for ALS_DIFF (so one has to physically adjust the DIFF_OFFSET slider)

DAY'S ACTIVITIES:

Addendum Notes

Bubba will address Chiller Yard alarm noted Sat night when he's in on Monday (change alarm setting?)

H1 Problems of the day:

SDF Diffs

SR3 Cage Servo

Locked H1 without this servo engaged (SR3 was saturating).  Sheila was able to slowly engage this while in lock.  The H1:SUS-SR3_M1_OPTICALALIGN_P_OFFSET SDF setpointpoint is 563.7, but to get this servo to go, it was moved to 562.2 (Sheila called this a "hot" state for SR3).  For future locks we want to go back to the "cold" value of 56.7.  This was done after the 1:27 Lockloss.  