Displaying report 1-1 of 1.
Reports until 04:03, Thursday 17 September 2015
H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 04:03, Thursday 17 September 2015 - last comment - 04:31, Thursday 17 September 2015(21609)
Locked again at NOMINAL_LOW_NOISE

After almost 12 hours of not locking, the ifo is back at 70Mpc. OMC locked at the right mode this time so I still have no idea what's wrong earlier. Terramon has just reported another 5.5M earthquake in Chile. We might lose lock again...

 

SDF is reporting 6 differences in ISI ITMX and ISI ITMY. Unable to go to Observe mode. I'm digging through the alog. 

Images attached to this report
Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 04:13, Thursday 17 September 2015 (21610)

I couldn't find anything about the change in ITM ISI. FM4 simply adds gain of 20dB everywhere with 0 phase. FM5 labeled DWH reduces gain at high frequency with some phase change (maximum phase change of -40dB at ~20 Hz). I'm just gonna go ahead and accept the changes since the interferometer seems happy (so far). Now Observing.

nutsinee.kijbunchoo@LIGO.ORG - 04:31, Thursday 17 September 2015 (21611)

The ifo hardly noticed the 5.5M earthquake. The violin fundamentals seem higher than normal but none seems to be ringing up. LLO recently joined us in locking. We are BACK in the game!

Images attached to this comment
Displaying report 1-1 of 1.