Reports until 08:06, Thursday 17 September 2015
H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 08:06, Thursday 17 September 2015 (21617)
Owl Shift Summary

TITLE:  Sep 17 OWL Shift 07:00-15:00UTC (00:00-08:00 PDT), all times posted in UTC

STATE Of H1: Observing at 77 Mpc

SUPPORT: Sheila

SHIFT SUMMARY: After 12+ hours of not locking, we are back in business. I redid the initial alignment followed the printed Initial Alignment Checklist on the desk after the seismic nosie came down to almost nominal because PRMI looked hopeless. LLO is still trying to acquire lock.

INCOMING OPERATOR: Patrick

Activity log:

8:00 Begin initial aligment. Adjusted PR3 to maximize COMM beatnote. Spent 10 minutes at INPUT_ALIGN without luck. Trended IM4 and PR2 back to the last time the ifo was locked. I brought IM4 back to where it was. Touched PR2 YAW to get 00 mode on As Air camera.

8:04 Darkhan left

9:11 Craig left

9:12 BS ISI WD tripped during MICH_DARK_LOCK twice. Requested down and waited until the optic became settled and moved on.

         ENGAGE_ASC_PART3 took ~5 minutes.

        Guardian stalled at DC_READOUT_TRANSITION (alog21608). OMC was not ready for handoff and was locked at the wrong mode. I called Sheila for help but the ifo lost locked shortly.

10:52 Locked at NOMINAL_LOW_NOISE

11:13 Back to Observing after I cleared the SDF diff.

13:15 Lockloss. More earthquake....

13:46 Locked at NOMINAL_LOW_NOISE

13:48 Undisturbed.

15:00 Hand off to Patrick.