Chasing Signs: H1 is missing the -1 in their Actuation Chain CTRL Chain
J. Kissel, D. Tuyenbayev, J. Betzwieser, S. Kandhasamy

We recently found out LHO has not included the LSC Output matrix in their matlab model of the DARM loop (see LHO aLOG 21601), and this resulted in a discrepant phase in the calculation of the time-dependent parameters. Independently, of the few hardware injections we've managed to test thus far, there remains a minus sign found in the H1 reconstruction (LHO aLOG 21616). Finally, Maddie has found that the sign of DELTAL_CTRL is different between the two observatories (no aLOG yet).

The messages: 
- We have found that CAL-CS *also* does *not* include this LSC OUTPUT MATRIX -1. We think this is an error, yet somehow the CAL_DELTAL_EXTERNAL is still showing sensible results, and we don't understand why.

- We believe this explains the missing sign in the inverse actuation filter. LHO has been inverting the DARM matlab model's version of the actuation function, which did *not* include the LSC output matrix, i.e. a -1, and hardware injections are injected upstream of this output matrix in the DARM path.

- We don't understand what we see when the CAL-CS installations comparing between sites (LHO does NOT account the output matrix, where LLO does, and both sites produce sensible DELTAL EXTERNAL ASDs).

Attached are screenshots of the CAL-CS MEDM screen, the replica of the LSC output matrix, and its actual counterpart in from the LSC overview screen, to prove to myself what is true. 

The path forward: 
- A sanity check: Take two transfer functions, DELTAL_CTRL to DELTAL_EXT and DELTA_RESIDUAL to DELTAL_EXTERNAL. Export them into matlab, add them and subtract them. Check if DELTAL_EXTERNAL would even notice if A was + or -. Our intuition says "yes, it should make some nasty bump or zero in the calibrated ASD."
- Make a sign table like LLO has in LHO aLOG 20587.
- Plot comparisons between both models, and make sure it makes sense.
- Figure out how to handle "the feedback minus sign" convention, to confirm that we're both obeying what's shown in LHO aLOG 21601
Images attached to this report