Reports until 03:34, Friday 18 September 2015
H1 General
corey.gray@LIGO.ORG - posted 03:34, Friday 18 September 2015 - last comment - 04:48, Friday 18 September 2015(21648)
5.1 & 6.3 Earthquakes From Chile (Mid-shift Summary)
Earthquakes ringing planet (& L1/H1 lockloss).
Comments related to this report
corey.gray@LIGO.ORG - 04:48, Friday 18 September 2015 (21649)

~10:50 Left to cook salmon and bagel/cream cheese, and set ISC_LOCK to DRMI

11:22 Came back to H1 locked on DRMI  (since 11:18)

NOTE:  So DRMI finally locked up, and on the 0.03-0.1 seismic band, the velocity was down to 0.1um/s. Recap:  

  • 0.03-0.1 Normally 0.01um/s
  • When EQ (over ~1hr) took this band to 0.1um/s, we had lockloss
  • EQ peaked at 1.0um/s(!)
  • Once this band lowered to 0.1um/s, H1 was able to lock DRMI

Observation Mode was set to Earthquake from 10:03-11:34 (should be more like 9:30-11:18, where 11:18-11:33 would be Lock Acquisition).

11:35 Back to Observation Mode (with a range trending toward 80Mpc).

ITM ISI GS13 SDFs ACCEPTED with HI gain.