Accidentally had test points open in observation mode
I just realized that I have had two LSC test point channels open since the beginning of this lock acquisition and in Observation Mode. I just turned them off.

20:52 UTC Stopped running H1:LSC-TR_X_NORM_OUT and H1:LSC-TX_Y_NORM_OUT test points in dataviewer. Checked that they are no longer present on the H1LSC_GDS_TP medm.
Comments related to this report
corey.gray@LIGO.ORG - 14:37, Friday 18 September 2015 (21660)

Whoa.  How do we know if we have test points up?  Heck, I might have been looking at these channels, too (or did I have non-test point channel versions of these channels?).  Is it bad to look at Test Points?  (if it is, is there a monitor to show us test points are being looked at?)

daniel.sigg@LIGO.ORG - 16:09, Friday 18 September 2015 (21664)

This is ok as long as we don't open way too many.