Activity Log: All Times in UTC (PT) 07:00 (00:00) Take over from TJ 07:09 (00:09) IFO locked at NOMINAL_LOW_NOISE, 22.7W, 71Mpc 07:16 (00:16) Set Intent Bit to Observing 08:17 (01:17) ETMY saturation 08:36 (01:36) ETMY saturation 09:43 (02:43) ETMY saturation 12:03 (05:03) ETMY saturation 13:33 (06:33) ETMY saturation 14:41 (07:41) ETMY saturation 14:45 (07:45) Christina moving 1-ton truck from Carpenters shop to LSB 15:00 (08:00) Turn over to Travis End of Shift Summary: Title: 09/21/2015, Evening Shift 07:00 – 15:00 (00:00 – 08:00) All times in UTC (PT) Support: None needed Incoming Operator: Travis Shift Summary: - 07:09 Relocked IFO after Lockloss (possible 6.3mag EQ in Chile. Set the Intent bit to Observing at 07:16 (00:16). - Smooth Owl shift last night. IFO locked in NOMINAL_LOW_NOISE at 22.7W with 68 to 72Mpc range for 8 hours. No significant seismic events during the shift. The wind was fluctuating between 20 plus mph and single digit speeds during the shift. This morning wind speeds are back up to high teens to low 20mphs. 6 ETMY saturation events during the shift, with minor effect on range.