Reports until 08:36, Thursday 24 September 2015
H1 SEI (SYS)
sebastien.biscans@LIGO.ORG - posted 08:36, Thursday 24 September 2015 (21885)
Locklosses between Sept 10th and 17th due to EQs

Following Sheila's entry (alog 21708), I've tried to figure out which locklosses where due to Earthquakes during the week of Sep 10th (ER8).

Out of the 22 locklosses seen this week, I've counted 6 locklosses due to EQs. Sheila counted 9, I'll double check my conclusions with her.

EQ Location Ground Velocity at LHO Status Lock Loss time
5.9 Alaska 5.99 microns/s Lockloss 1125916264.5625
5.2 Mexico 1.08 microns/s Lockloss 1126042739.0625
5.7 New Zealand 1.16 microns/s Lockloss 1126127070.8125
6.3 Indonesia 3.20 microns/s Lockloss 1126427496.4375
6.1 Papua New Guinea 2.90 microns/s Lockloss 1126448905.3125
8.3 Chile 170 microns/s Lockloss + SEI trip 1126480080.5625

 

The ground velocities represent the maximum amplitude predicted by the Seismon software.  These predictions could be inaccurate by a few percents.

Six examples is not enough to do some accurate statistics, but the behavior observed during ER8 doesn't contradict the conclusions drawn from ER7 (see DCC T1500230). My conclusions were:

Note: among the 16 remaining locklosses, some of them are due to a high ground motion, but EQ is not the cause (wind? human activity?).