The attached files are plots of the ITMY L1 WhiteNoise TFs measured last night. The parameters were significantly different from previous measurements of the TFs from the L1 stage. The drive amplitudes were tweaked for better coherence to distinguish the resonances. Coherence is decent for the L DoF and good enough to see the resonance peaks. The Pitch and Yaw DoFs have much better coherence, as expected. The locations of the peaks coincide well with the models for the most part. ----------------------------------------------------------- DTT template files: /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ITMY/SAGL1/Data '2012-02-01_H2SUSITMY_L1_*DOF*_TF.xml' PDFs of Plots: /ligo/svncommon/SusSVN/sus/trunk/QUAD/H2/ITMY/SAGL1/Results/ '2012-02-08_L1_Long_TF_200k_amp_0to1000Hz_WhiteNoise.pdf' '2012-02-08_L1_Pitch_TF_15k_amp_0to1000Hz_WhiteNoise.pdf' '2012-02-08_L1_Yaw_TF_5k_amp_0to1000Hz_WhiteNoise.pdf'