Reports until 11:25, Friday 10 February 2012
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 11:25, Friday 10 February 2012 (2201)
Valve swap horizontal NW actuator - HEPI BSC8

In alog #2034, we mentioned an issue probably created by a malfunctioning actuator in corner 2 (Horizontal - NW). Two modifications were made since the issue was mentioned:

-          Disconnecting and reconnecting the actuators (Horizontals and Verticals separately)

-          Swapping the actuator valve of horizontal actuator in the NW corner

After rerunning the test (attached figure), you can notice that corner 2 (NW) behaves more linearly (not the case of corner 3 after the actuators reinstallation).

Non-image files attached to this report