Displaying report 1-1 of 1.
Reports until 23:53, Friday 25 September 2015
H1 INJ (DetChar, INJ)
christopher.biwer@LIGO.ORG - posted 23:53, Friday 25 September 2015 - last comment - 07:38, Monday 28 September 2015(21965)
Hardware injection testing for lower frequency waveforms
We tested a set of waveforms to see if they would saturation the ETMY ESD.

Test the 15Hz waveform

Previously we have tested a waveform that began at 30Hz, see aLog 21838. It was requested we try it from 15Hz instead of 30Hz.

Here are the commands I ran for testing the 15Hz waveform:
ezcawrite H1:CAL-INJ_TINJ_TYPE 1
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/coherenttest1from15hz_1126257408.out 0.1 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/coherenttest1from15hz_1126257408.out 0.25 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/coherenttest1from15hz_1126257408.out 0.5 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/coherenttest1from15hz_1126257408.out 1.0 -d -d >> log3.txt 
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/coherenttest1from15hz_1126257408.out 1.0 -d -d >> log3.txt 
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/coherenttest1from15hz_1126257408.out 1.0 -d -d >> log3.txt

The start times of the injections from the log file (log3.txt):
SIStrOpen: Waveform starts at GPS=1127276638, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127276799, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127277026, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127277293, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127277517, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127277840, epoch=0, sample=0

I did not notice any ESD saturations.

John's waveforms

John V. has also provided 10 waveforms that I tested, see aLog 21964.

Cautiously testing the first waveform

Here are the command I entered as I slowly scaled up the first waveform's amplitude: 
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 0.2 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 0.5 -d -d >> log3.txt 
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 0.75 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 0.85 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 1.0 -d -d >> log3.txt

The start times for these injections:
SIStrOpen: Waveform starts at GPS=1127278105, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127278209, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127278748, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127279093, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127279520, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127279644, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127280123, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127280433, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127281232, epoch=0, sample=0

The injection that began at 1127280433 was near an ETMY alert from the robot voice. The ETMY alert happened a bit after the injection happened. SO I waited, I repeated the same injection, and there was no alert.

I did one of these injections with a padding of 10 minutes so if the search groups are going to followup one of these injections in more detail this would be a good choice:
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior0_1126259455.out 1.0 -d -d >> log3.txt # gave this guy a bit of time

The start time of this injection is:
SIStrOpen: Waveform starts at GPS=1127281956, epoch=0, sample=0

Testing the other nine waveforms

Then I tested the remaining 9 waveforms by beginning with a scale factor of 0.3333 and incrementing to 1.0. I did these with little spacing between the injections so I do not think this set is worth the analysis groups following up. However, I think the injections with scale factor 1.0 should be looked at for ESD saturation (I believe Andy has a script for that):
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior1_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior1_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior1_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior2_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior2_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior2_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior3_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior3_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior3_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior4_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior4_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior4_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior5_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior5_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior5_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior6_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior6_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior6_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior7_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior7_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior7_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior8_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior8_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior8_1126259455.out 1.0 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior9_1126259455.out 0.3333 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior9_1126259455.out 0.6666 -d -d >> log3.txt
awgstream H1:CAL-INJ_TRANSIENT_EXC 16384 ../H1/posterior9_1126259455.out 1.0 -d -d >> log3.txt

The start times of these injections:
SIStrOpen: Waveform starts at GPS=1127282013, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282066, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282120, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282173, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282226, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282278, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282326, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282377, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282422, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282476, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282517, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282577, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282631, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282681, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282727, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282770, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282819, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127282964, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283007, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283048, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283089, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283160, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283204, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283245, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283292, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283338, epoch=0, sample=0
SIStrOpen: Waveform starts at GPS=1127283440, epoch=0, sample=0

As I did these injections I had the SUS-ETMY_L3_ESDOUTF_LL_OUT channel open in dataviewer. I did not see any injection go above the 90000 counts. The highest was posterior0*.out which was near 80000 counts.
Non-image files attached to this report
Comments related to this report
john.veitch@LIGO.ORG - 02:28, Saturday 26 September 2015 (21969)

I am going to follow up the injections I passed to Chris. Assuming the "start time" is the time at the 1st sample of the injection file (and not the 1st non-zero sample) the end times of the increasing amplitude posterior0 injections should be around

[1127278112.46, 1127278216.46, 1127278755.46, 1127279100.46, 1127279527.46, 1127279651.46, 1127280130.46, 1127280440.46, 1127281239.46, 1127281963.46]
 
and for the scan through posterior injections 1-9 with increasing amplitude they are
[1127282020.46, 1127282073.46, 1127282127.46, 1127282180.46, 1127282233.46, 1127282285.46, 1127282333.46, 1127282384.46, 1127282429.46, 1127282483.46, 1127282524.46, 1127282584.46, 1127282638.46, 1127282688.46, 1127282734.46, 1127282777.46, 1127282826.46, 1127282971.46, 1127283014.46, 1127283055.46, 1127283096.46, 1127283167.46, 1127283211.46, 1127283252.46, 1127283299.46, 1127283345.46, 1127283447.46]
 
I'm going to just run all of these since they should be quite cheap to do. I'll post an update when the runs complete.
andrew.lundgren@LIGO.ORG - 07:38, Monday 28 September 2015 (22015)DetChar, INJ
The only ETMY overflows during the injection periods were:

1127278436.8
1127280154.9 (also overflowed ETMY L2 and OMC DCPD)
1127282847.5

None were related to the injections.