Detailed here. This process change has been executed. Confirmed the Rogue excitation does not come on and again the GS13s needed to be switched to low gain. Also, even in low gain, the ISI still tripped on the CPS with the GS13 pretty rung up too. I set the ISI guardian to damping only for a few minutes and then it made it to Isolated.
Platform back to nominal with GS13 gain correct in High No whitening.