john.zweizig@LIGO.ORG - posted 11:42, Tuesday 29 September 2015 (22066)
DMT restarted with minor config changes
I have restarted all the dmt processes. This is to fix problems seen at LHO in which disk write delays were interfering with the h(t) and DQ segment generation. The changes made were:

 1) remove diagnostic logging from the multicast receiver processes
 2) write the DQ xml files to a local disk and then move them to the gds RAID system as a separate process (not time critical).

A change of the h(t) calibration filter files was also planned, but this will be done after final calibration group tests.