Hardware Injection computers undergoing maintenance
The h1hwinj1 computer is currently undergoing maintenance and testing.  A fresh checkout of the Details directory has been installed, with the old Details directory being moved to Details-old.  Testing of psinject and run_tinj will be performed to get these under monit control. 
Comments related to this report
james.batch@LIGO.ORG - 13:29, Tuesday 29 September 2015 (22072)
The psinject and run_tinj are now under control of monit.  

Changes were made to the SOURCEME_LHO.sh script to correct paths to shared libraries, changes checked in.  Recompiled run_tinj and tinj using instructions in the source files.

Final state, psinject and run_tinj are not running, but under monit control. The output of the H1CALCS_INJ_HARDWARE filter has been turned on, with no injections running.