Parameters for report:
GPS Start Time = 1127423695 # Beginning of time span, in GPS seconds, to search for injections
GPS End Time = 1127510095 # Ending of time span, in GPS seconds, to search for injections
Check Hanford IFO = True # Check for injections in the Hanford IFO frame files.
Check Livingston IFO = True # Check for injections in the Livingston IFO frame files.
IFO Coinc Time = 0.01 # Time window, in seconds, for coincidence between IFO injection events.
Check ODC_HOFT = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in HOFT frames.
Check ODC_RAW = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in RAW frames.
Check ODC_RDS = True # Check ODC-MASTER_CHANNEL_OUT_DQ channel in RDS frames.
Check GDS_HOFT = True # Check GDS-CALIB_STATE_VECTOR channel in HOFT frames.
Report Normal = True # Include normal (IFO-coincident, consistent, and scheduled for network injections and consistent and scheduled for IFO injections) injections in report
Report Anomalous = True # Include anomalous (non-IFO-coincident, inconsistent, or unscheduled) injections in report
----
No scheduled injections or non-occurring injections were found.
There was a CAL_INJ reset that occurred only in H1, CALRESET 1127480460.000 (H1). However, it has the anomaly that it appears in ODC HOFT and GDS HOFT frames but not in ODC RAW or ODC RDS frames. This same anomaly was observed with several CBC injections in L1 during the daily period 1127163296 - 1127249696.
The anomalies reported here are likely due to the same bug that caused the anomalies as reported in https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=21971.