At H1 tinj is being paused and cannot be re-enabled the second injection did go through at L1. We remembered to change CAL-INJ_EXTTRIG_ALERT_TIME. So we are removing injections that would have failed from the schedule.
The schedule now reads:
1127783813 1 1.0 coherentbbh0_1126259455_
1127784860 1 1.0 coherentbbh1_1126259455_
1127789367 1 1.0 coherentbbh6_1126259455_
christopher.biwer@LIGO.ORG - 18:47, Thursday 01 October 2015 (22167)DetChar, INJ
Argh! The version of ext_alert.py running at LHO is evidently an older version which is still setting H1:CAL-INJ_TINJ_PAUSE in addition to H1:CAL-INJ_EXTTRIG_ALERT_TIME. tinj imposes an automatic 1-hour pause based on H1:CAL-INJ_EXTTRIG_ALERT_TIME; setting H1:CAL-INJ_TINJ_PAUSE is an independent pause mechanism, intended for humans to use. This is the same issue we had for last week's hardware injection tests (alog 21932). It's too bad the software wasn't updated to match the current version which is running at LLO.