DARMOLGTF and PCAL sweep during LLO Down

S. Karki, C.Biwer

Used the single IFO time to do the regular DARMOLGTF  and PCALY to DARM sweep measurement for regular calibration purpose. We also did a sweep at PCALX and used the measurement to create inverse actuation filter.

The coherence dropped to .95 during PCALY sweep at around 35 Hz because I forgot to turn of the x_ctrl line. Oops!

The measurement files are committed to the SVN:

DARMOLGTF: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Measurements/DARMOLGTFs/2015-10-01_H1_DARM_OLGTF_7to1200Hz.xml

PCALY SWEEP: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Measurements/PCAL/2015-10-01_H1_PCALY2DARMTF_7to1200Hz.xml

PCALX SWEEP: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Measurements/PCAL/2015-10-01_H1_PCALX2DARMTF_7to1200Hz.xml