TITLE: 10/4 DAY Shift: 15:00-23:00UTC (00:00-8:00PDT), all times posted in UTC
STATE of H1: Observation Mode with Avg of 74Mpc
Outgoing Operator: JimW
Support: Vinny
Quick Summary: useism continues a slow trend down (at about 0.15um/sec). Winds hovering around 12mph.
Terramon has just come up with a RED warning of a 5.6 Peruvian earthquake who's Rayleigh wave is due here in a minute (0.7um/s), due at 15:30:38UTC. We'll see what happens.
L1 just went down at 15:30. Terramon said the EQ's Rayleigh waves (of 1.4um/s) would arrive there at 15:17UTC.
So we might not be out of the woods yet...watching 0.03-0.1Hz (all three axis have yet to move up at the same time and all are still under 0.1um/s...I've seen us drop out when all three go above that velocity...but that was a few weeks ago before the DHARD filter).
No signs of anything on tidal or ASC control strip tools either.