corey.gray@LIGO.ORG - posted 08:27, Sunday 04 October 2015 - last comment - 08:46, Sunday 04 October 2015(22219)
Transition to DAY Shift Update

TITLE:  10/4 DAY Shift:  15:00-23:00UTC (00:00-8:00PDT), all times posted in UTC     

STATE of H1:  Observation Mode with Avg of 74Mpc

Outgoing Operator:  JimW

Support:  Vinny

Quick Summary:  useism continues a slow trend down (at about 0.15um/sec).  Winds hovering around 12mph.  

Comments related to this report
corey.gray@LIGO.ORG - 08:29, Sunday 04 October 2015 (22220)

Terramon has just come up with a RED warning of a 5.6 Peruvian earthquake who's Rayleigh wave is due here in a minute (0.7um/s), due at 15:30:38UTC.  We'll see what happens.

corey.gray@LIGO.ORG - 08:32, Sunday 04 October 2015 (22221)

L1 just went down at 15:30.  Terramon said the EQ's Rayleigh waves (of 1.4um/s) would arrive there at 15:17UTC.  

So we might not be out of the woods yet...watching 0.03-0.1Hz (all three axis have yet to move up at the same time and all are still under 0.1um/s...I've seen us drop out when all three go above that velocity...but that was a few weeks ago before the DHARD filter).  

No signs of anything on tidal or ASC control strip tools either.

corey.gray@LIGO.ORG - 08:46, Sunday 04 October 2015 (22223)

It's been 15min since the R-wave arrival estimate, I'm assuming we rode through the EQ.  (it was barely observable in here on seismic bands, range, striptools).  Time to make breakfast/coffee.