daniel.sigg@LIGO.ORG - posted 14:45, Tuesday 06 October 2015 - last comment - 15:37, Tuesday 06 October 2015(22276)
New Temperature Monitors in Electroncis Rooms

Richard et al hooked up the missing temperature probes in the electroncis rooms. Attached is the new medm screen.

Channel names

                H1:PEM-C_MSR_RACK1_TEMPERATURE
                H1:PEM-C_MSR_RACK2_TEMPERATURE
                H1:PEM-C_CER_RACK1_TEMPERATURE
                H1:PEM-C_SUP_RACK1_TEMPERATURE
                H1:PEM-X_EBAY_RACK1_TEMPERATURE
                H1:PEM-X_EBAY_RACK2_TEMPERATURE
                H1:PEM-Y_EBAY_RACK1_TEMPERATURE
                H1:PEM-Y_EBAY_RACK2_TEMPERATURE
 

Images attached to this report
Comments related to this report
richard.mccarthy@LIGO.ORG - 15:37, Tuesday 06 October 2015 (22279)
In the corner station electronics room the sensors are located:
CER_RACK1  below the mezzanine above space in front of ISC racks.
SUP_RACK1  above mezzanine center of the wall just below one of the air handlers.  

In the end stations

Rack1 is above the electronics racks mounted to the bottom of the cable tray
Rack2 is above the DC power supply racks mounted to the bottom of the cable tray

In the MSR
Rack1 is above Rack 2
Rack2 is above rack 11

EndX input module has a problem.  The disconnected probe did not read the same value as the others and now that the RTDs are connected the signal is glitching.  To fix this will require opening the box and replacing the module.  This will take down the entire EX beckhoff system as this is the main link to the corner