Uptime of the Slow Controls System

The attached plot shows the elapsed time of the 3 EtherCAT systems over the past 65 days. The start time is indicated about 64 days ago and no software change has been applied since then. We can see that both the corner and EX were up the entire time, wheres EY had a single downtime, when a hardware failure prompted the repalcement of a terminal. The computers and software caused no downtime.