Receiver part added to ASC model for A2L

[Sheila, Jenne]

This morning, we discovered that the new a2l script from LLO wasn't working, because we didn't have DARM_CTRL piped over to the ASC model. 

The OMC model already had a sender part, so we only needed to add the receiver [WP 5549].  The screenshots below show the "before" and "after" of the change. 

We compiled the model, and Dave restarted it and the DAQ for us a few minutes ago. 

Images attached to this report