Reports until 18:01, Thursday 08 October 2015
H1 GRD
jenne.driggers@LIGO.ORG - posted 18:01, Thursday 08 October 2015 (22358)
SDF diffs after Commissioning Day

After today's Commissioning Day activities, we had quite a few SDF differences to clear out. 

For the ASC, we accepted several things that will be regularly used for the A2L measurements.  These are all channels of the ASC-ADS_ sub-subsystem.  The things we accepted will have no effect on the interferometer, since during observation we don't use this system at all.  We accepted things like the frequencies of the A2L measurements, the ramp times, and the matrix elements.  Note that the "CLKGAIN", which is the acutal oscillator amplitude, is still set to zero in SDF, so if any excitation is happening, it'll be flagged in SDF. 

I also accepted the new IM2 Pit and Yaw offset values, which were set after Keita and Cheryl did their IMC work today.  (Since the IMC pointing moved slightly after their WFS work, they compensated by moving IM2 a bit).  Keita and I also accepted several diffs from the ASCIMC model, that were changed as a result of their WFS work today.