Monitor Test Point for CAL-DELTAL_EXTERNAL Opened Briefly While In Observation Mode
J. Kissel, M. Oliver

Miquel and I are doing some fun Sunday afternoon investigations of the 1 [Hz] comb for the CW group (see LIGO wiki page). Since we see that the power of the comb evolves with time, we've gathered some DELTAL EXTERNAL data as a test point to compare it against the version stored in the frames. Accessing the test point via DTT opened up a test point, naturally. One would have nominally expected opening up test points on any front end to take us out of observation mode BUT CAL-DELTAL_EXTERNAL happens to be computed on the same front end as the continuous wave injections, which -- because they need to access the H1:CAL-INJ_CW_EXC test point continuously -- has been flagged as "OK to have test points activated." (Note, this is why Giles, the H1 IFO automated voice robot, announced that CW injections had started when I hit "start" on the first bit of data gather in the DTT session). Of course, this is a monitor test point, so it had zero effect on the functionality/operation of the IFO, so remaining in observation mode was totally acceptable (even though admittedly, we didn't think of it when getting started). 

The test point was activated at 19:25 UTC (12:25 PDT) to 20:22 UTC (01:22 PDT).

Stay tuned for analysis of the data.