Reports until 20:54, Sunday 11 October 2015
H1 INJ (DetChar, INJ)
christopher.biwer@LIGO.ORG - posted 20:54, Sunday 11 October 2015 - last comment - 21:38, Sunday 11 October 2015(22424)
Starting hardware injection test
Beginning hardware injection test. The schedule will be updated with:

1128657857 1 1.0 ringburstinj1a_1126259456_
1128658037 1 1.0 ringburstinj1b_1126259456_
1128658217 1 1.0 ringburstinj2a_1126259456_
1128658397 1 1.0 ringburstinj2b_1126259456_
1128658577 1 1.0 ringburstinj3a_1126259456_
1128658757 1 1.0 ringburstinj3b_1126259456_
1128658937 1 1.0 ringburstinj4a_1126259456_
1128659117 1 1.0 ringburstinj4b_1126259456_
1128659297 1 1.0 ringburstinj5a_1126259456_
1128659477 1 1.0 ringburstinj5b_1126259456_
1128659657 1 1.0 ringburstinj6a_1126259456_
1128659837 1 1.0 ringburstinj6b_1126259456_
1128660017 1 1.0 ringburstinj7a_1126259456_
1128660197 1 1.0 ringburstinj7b_1126259456_
1128660377 1 1.0 ringburstinj8a_1126259456_
1128660557 1 1.0 ringburstinj8b_1126259456_
1128660737 1 1.0 ringburstinj9a_1126259456_
1128660917 1 1.0 ringburstinj10a_1126259456_
1128661097 1 1.0 ringburstinj11a_1126259456_
1128661277 1 1.0 ringburstinj12a_1126259456_
1128661457 1 1.0 ringburstinj13a_1126259456_
1128661637 1 1.0 ringburstinj14a_1126259456_
1128661817 1 1.0 ringburstinj15a_1126259456_
1128661997 1 1.0 ringburstinj16a_1126259456_
Comments related to this report
christopher.biwer@LIGO.ORG - 21:38, Sunday 11 October 2015 (22425)DetChar, INJ
The plan was to do the injections 180s apart. tinj cannot do injections this close together so some injections were skipped.

The following injections were successful:
1128657857 1 1.0 ringburstinj1a_1126259456_
1128658217 1 1.0 ringburstinj2a_1126259456_
1128658577 1 1.0 ringburstinj3a_1126259456_
1128658937 1 1.0 ringburstinj4a_1126259456_
1128659297 1 1.0 ringburstinj5a_1126259456_

The following injections were skipped and thus not successful:
1128658037 1 1.0 ringburstinj1b_1126259456_
1128658397 1 1.0 ringburstinj2b_1126259456_
1128658757 1 1.0 ringburstinj3b_1126259456_
1128659117 1 1.0 ringburstinj4b_1126259456_
1128659477 1 1.0 ringburstinj5b_1126259456_

This injection was scheduled during the GRB alert. It was not injected at H1 but it wasn't stopped in time at L1:
1128659657 1 1.0 ringburstinj6a_1126259456_

A GRB alert happened so I removed the following injections from the schedule:
1128659837 1 1.0 ringburstinj6b_1126259456_
1128660017 1 1.0 ringburstinj7a_1126259456_
1128660197 1 1.0 ringburstinj7b_1126259456_
1128660377 1 1.0 ringburstinj8a_1126259456_
1128660557 1 1.0 ringburstinj8b_1126259456_
1128660737 1 1.0 ringburstinj9a_1126259456_
1128660917 1 1.0 ringburstinj10a_1126259456_
1128661097 1 1.0 ringburstinj11a_1126259456_
1128661277 1 1.0 ringburstinj12a_1126259456_
1128661457 1 1.0 ringburstinj13a_1126259456_
1128661637 1 1.0 ringburstinj14a_1126259456_
1128661817 1 1.0 ringburstinj15a_1126259456_
1128661997 1 1.0 ringburstinj16a_1126259456_