I remotely logged in from LLO and modified the H2SUSITMY.txt file located in /opt/rtcds/lho/h2/chans/ directory, which contains the ITMY suspension control filters. I removed 4 AntiAcqL1 filters which shouldn't have been there and which may have been installed awhile back incorrectly (possibly by the prepare.m script I've since modified, possibly by someone by hand). Testing with the current suspension prepare.m script in /ligo/svncommon/SusSVN/sus/trunk/Common/MatlabTools does not generate this filter, so future use to prepare filters for other QUAD optics should not have this problem. I copied the new H2SUSITMY.txt to /opt/rtcds/lho/h2/userapps/release/sus/h2/filterfiles and checked it into the svn.