Laser Status:
SysStat is good
Front End power is 32.33W (should be around 30 W)
Frontend Watch is GREEN
HPO Watch is RED
PMC:
It has been locked 5.0 days, 13.0 hr 11.0 minutes (should be days/weeks)
Reflected power is 2.032Watts and PowerSum = 25.77Watts.
FSS:
It has been locked for 0.0 days 1.0 h and 40.0 min (should be days/weeks)
TPD[V] = 1.508V (min 0.9V)
ISS:
The diffracted power is around 9.368% (should be 5-9%)
Last saturation event was 0.0 days 1.0 hours and 39.0 minutes ago (should be days/weeks)
Note: This report is being made on maintenance day. IFO is unlocked.