Reports until 12:50, Tuesday 13 October 2015
H1 INJ (CAL, INJ, SYS)
duncan.macleod@LIGO.ORG - posted 12:50, Tuesday 13 October 2015 (22479)
Updated ODC EPICS configuration for PINJX

[Jeff K, Duncan M]

ODC EPICS changes

With Jeff's assistance (and that of the on-duty operator) I have remotely updated the EPICS configuration for ODC to commission the state monitoring for the new PINJX infrastructure [alog 22445 22465 22470 22473].

Changes were made to EPICS records in the h1calex, h1iscex, and h1odcmaster models as follows

These changes have been monitored and accepted in SDF for the relevant models and can serve as a reference for L1 when the same changes are made next week.

ODC MEDM changes

Associated changes were made to the ODC MEDM screens in order to show the CAL_X ODC input. This required separating the SYS_CUST_ODC_MASTER_END.adl screen into separate screens for MASTER_X and MASTER_Y (no CAL_Y ODC). These changes were committed to userapps as r11886.