TITLE: 10/14 day Shift: 15:00-23:00UTC
STATE of H1: Low-noise for 4 hours, periodic commissioning during single IFO time
Support: Usual control room population
Quick Summary:
Quiet, busy shift with lots of noise investigations, H1 was well behaved
Shift Activities:
16:04 lockloss
18:03 LLO has a bounce mode rung up, so we go to commissioning
18:05 Evan turning on BLRMS filters, Richard to EY, Robert to LVEA
19:00 Gerardo to EX, JeffB to LVEA
19:00 Robert to EX for tamping
21:10 JeffB to LVEA
21:00 Evan trying some BLRMS filters
22:30 Robert turning HVAC off, done 22:50